WWTT--11001100CC22 GGGSSSMMM AAALLLAAARRRMMM SSSYYYSSSTTTEEEMMM User Manual
WT-1010C2 USER MANUAL When the terminal is ready to use, it will display as below WT-1010 Battery
WT-1010C2 USER MANUAL The WT-1010C2 can be programmed manually by a connected normal telephone. Note: Before commencing program
WT-1010C2 USER MANUAL HAND FREE… Programming Mode 2) Reset the Main Unit To reset the unit, you can press *15* to procee
WT-1010C2 USER MANUAL TEL: OK 1# Number programmed successfully You may continue to program administrator number 2, 3, 4, 5, 6, 7 a
WT-1010C2 USER MANUAL ANY – ON&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# ANY – ON&
WT-1010C2 USER MANUAL Simply input digits and ended with # TIME: 08 : 30 : 00 OK 8) Enable/Disable the feature of Password Request when
WT-1010C2 USER MANUAL SECT: 11111111 Example: To turn on this function for all recipients Simply input 11111111# SECT: 11111111 OK
WT-1010C2 USER MANUAL 11) Setting the Burst On and Burst Off time of DTMF tones The Burst ON and Burst OFF timing of the sending Contact-ID can
WT-1010C2 USER MANUAL Simply input digits and ended with # DSTM: 12 : 00 : 00 OK 13) Enable/Disable the function of dialing the programm
WT-1010C2 USER MANUAL DTIMEM – ON&OFF: 1 OK 15) Setting for Calling a group of administrator numbers To program the unit to dial a
2WT-1010C2 USER MANUAL Sketch of the WT-1010C2 POWER INDICATOR (RED) The indicator is illuminated when mains power is present ANTENNA The anten
WT-1010C2 USER MANUAL PST: ME: 1 OU: 1 AL: 1 CA: 1 OK Note: “ME” stands for generation of SMS when PSTN failed “OU”
WT-1010C2 USER MANUAL IN1: OP: CL: AL: CA: IN1: OP: 1 CL: 1 AL: 1 CA: 1 Example: Setting the input 1 to generat
WT-1010C2 USER MANUAL RLY1: 00050 RE: 1 OK Note: “ RE:” stands for generation of SMS when relay off, value: ON (1) or OFF (0) You may contin
WT-1010C2 USER MANUAL NEW AREA: 03 Enter area code and ended with # NEW AREA: OK Area code programmed successfully 22) Setting th
WT-1010C2 USER MANUAL Example: To set the delay time at 7 seconds Simply press 00007# DTTRANSMIT: 00007 OK 24) Setting the Al
WT-1010C2 USER MANUAL 26) Inquire the status of the Recipients that will receive Alert Messages To inquire the status of the recipients, you c
WT-1010C2 USER MANUAL 5. WT-1010C2 Configuration Instructions (Via SMS) You can program the WT-1010C2 via SMS commands using your phone. Any progr
WT-1010C2 USER MANUAL Text Command: *ANY?#X X stands for ON (1) or OFF (0) value When *ANY?#1 is applied, means only administrator can access the s
WT-1010C2 USER MANUAL 5.4 Turn Off the feature of Password Request when Accessing the System By default every time calling the system, it will pr
WT-1010C2 USER MANUAL *ACCT#9999 Return Message ACCT:9999 Note: Please refer to page 43 for Contact-ID Protocol for WT-1010C2 5.6 Setting the B
3WT-1010C2 USER MANUAL Wiring Diagram A (Main Unit) WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : [email protected] COPYRIGHT ©
WT-1010C2 USER MANUAL When *PSC?#1 is applied, it will dial the administrator/central station number when PSTN failed. When *PSC?#0 (Default) is app
WT-1010C2 USER MANUAL When *PSOF#1 is applied, means it has +V output via PIN15 when PSTN failed. When *PSOF#0 (Default) is applied, would mean turne
WT-1010C2 USER MANUAL When *ACCA#0 (Default) is applied, it will not dial the administrator/central station number when AC failed. To enable this fu
WT-1010C2 USER MANUAL Return Message ACALARM-ON 5.8.4 Auxiliary Power Down Output Facility via PIN7 In additional to the alarm and text alert o
WT-1010C2 USER MANUAL When *DTM?#1 is applied, it will send the status of the system via SMS to the programmable administrator/central station numbe
WT-1010C2 USER MANUAL When *DTC?#1 is applied, it will dial the programmable administrator/central station number at the programmed report time inte
WT-1010C2 USER MANUAL *INR[N]#X N stands for Input number 1 – 3 X stands for ON (1) or OFF (0) value Example: When *INR1#1 is applied, means when I
WT-1010C2 USER MANUAL 5.10.4Editing the Inputs Alert Messages (Up to 50 Characters) The Input Alert Message can be edited and programmed up to 50
WT-1010C2 USER MANUAL 5.11 Output Settings 5.11.1 Activate Output Relay to Stay On for a Specific Time To activate the output relay, you can s
WT-1010C2 USER MANUAL When *RLR1#0 is applied, means when Relay 1 has turned off, it will not send any message to the programmable administrator numb
WT-1010C2 USER MANUAL Please check the following packing list: Name Quantity UnitWT-1010C2 Main Unit 1 set Telephone l
WT-1010C2 USER MANUAL Return Message AREA-OK 5.14 Setting the Function of Adding Area Code when Transmitting an Alarm The system has the functi
WT-1010C2 USER MANUAL *DAIL-TIME#=00007 5.16 Setting the Alarm Time for Audible Alarm (Default: 600 seconds) The alarm siren can be set to deter
WT-1010C2 USER MANUAL 5.17.3 Checking Signal Strength To check the signal strength of the unit, you can send the following SMS command to the unit
WT-1010C2 USER MANUAL 5.17.7 Setting for Dialing a group of administrator numbers when PSTN/AC failed or Auto Test To program the uni
WT-1010C2 USER MANUAL 6. Digital Communication Standard - Contact ID Protocol for WT-1010C2 Objectives a) Provide information regarding events th
WT-1010C2 USER MANUAL • A burst of 1400 Hz. ±3% tone with a duration of 100 msec. ±5% • A pause of 100 msec. ±5% • A burst of 2300 Hz. ±3% tone wi
WT-1010C2 USER MANUAL Data Transmission Frequencies – Standard DTMF Signaling Digit Low Tone (Hz.) High Tone (Hz.) Digit Value 0 941 1336 10 1 697 1
WT-1010C2 USER MANUAL Note: Transmitters shall accept a frequency error of at least ± 5% to ensure back compatibility with older receivers Maximum N
WT-1010C2 USER MANUAL Warranty Witura Corporation Sdn Bhd guarantees all WT-1010C2 GSM Fixed Wireless Terminal against defective parts and w
WT-1010C2 USER MANUAL 1. Introduction to the WT-1010C2 GSM Alarm System The WT 1010C2 GSM Terminal is a wireless communicator for alarm and fire p
WT-1010C2 USER MANUAL 2. Main Features of the WT-1010C2 1. Panel compatibility - Allows any contact ID alarm panel to transmi
WT-1010C2 USER MANUAL 7. Sends text messages to user programmable cell phone number (SMS): The WT-1010C2 can be programmed to send a SMS to a progra
WT-1010C2 USER MANUAL 3.2) WT-1010C2 Inputs and Outputs Wiring Instructions ZONE1(RLY1), ZONE2 (RLY2), ZONE3 (RLY3) Remote Controlling Outputs C
WT-1010C2 USER MANUAL Inputs and Outputs Wiring Diagram Note: Installing the SIM Card. Please be sure the initial 4 digit PIN code of SIM card