WT-9001 IP65 GSM Remote Control And Alarm System
WT-9001 IP65 – USER MANUAL – Rev. 3.4 – Technical Support: technical@witura.com
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Note: It is required to reset the Counter Alert Value (*CLA#) each time you change the
input function. For more details please refer to page 24
The system has the function to sound the connected audible siren when input triggered.
This output is available on the connection PIN3 and ground on the main board. To turn
On/Off this function, you can send the following SMS command to the unit.
Text Command:
*ALM[N]#X
N stands for Input number 1 – 8
X stands for ON (1) or OFF (0) value
When *ALM1#1 is applied, means audible alarm will sound when Input 1 triggered.
When *ALM1#0 (Default) is applied, means audible alarm will not sound when Input 1
triggered.
The alarm siren can be set to determine how long the siren will remain active and this
can be done by sending the following SMS command to the unit.
Text Command:
*ALTM#XXXXX
XXXXX stands for 5 digits value: The number of seconds (00000-65535)
Example:
When *ALTM#03600 is applied, means the audible alarm will sound for 1 hour when
triggered
The system has the function to send a text alert and also sound the audible siren in the
event the main power is lost and the system is relying on battery back up.
It is also possible to activate and deactivate this function by sending the unit an SMS
Message.
5.5.1 Turning the Audible Siren Functions On/Off When Inputs Triggered
5.5.2 Setting the Alarm Time For Audible Alarm (Default: 600 seconds)